Sign In | Join Free | My entremaqueros.com
China XI'AN BEICHENG ELECTRONICS CO.,LTD logo
XI'AN BEICHENG ELECTRONICS CO.,LTD
The Best Quality, The Best Service!
Site Member

5 Years

Home > Multifunction Process Calibrator >

High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibrator

XI'AN BEICHENG ELECTRONICS CO.,LTD
Contact Now

High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibrator

Brand Name : VICTOR

Model Number : VICTOR 05S

Certification : CE

Place of Origin : CHINA

MOQ : 1pcs

Price : USD137/pc

Payment Terms : T/T, Western Union, L/C, Paypal

Supply Ability : 3000pcs available

Delivery Time : 5 to 30 days

Packaging Details : 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 10KG/carton

Color : Blue or Orange and Black

Size : 180*90*47mm

Product Name : Loop Calibrator

Model No. : VICTOR 05S

Packing Details : 10pcs/Carton; Carton Size: 39.5*38.5*26cm

Accuracy : 0.05% accuracy

Weight : Approx. 900 g (including batteries)

Power supply : 2*1.5V AA Alkaline battery

Contact Now

High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator

VICTOR 05S Loop Calibrator high precision Voltage Current Simulation transmitter handheld automatic signal generator

VC05S LOOP Calibrator

Basic characteristics of the product

  • Input measurement characteristics
  • Basic functions

DC voltage DCV, DC current DCI

  • The maximum measurement accuracy is 0.05% and the measurement display is 5 digits.
  • Measurement rate: 2-3 times/sec.
  • Loop detection function, internal 24V circuit power supply, and simultaneous measurement of current.
  • mA has a percentage display mode.
  • Analog output characteristics
  • Basic functions

DC current DCI

The maximum measurement accuracy is 0.05% and the measurement display is 5 digits.

  • Output settings can be manually increased or decreased by position.
  • DCI output includes active output (internal 24V power supply) and passive output (external 24V power supply).
  • mA has a percentage display mode.
  • During DCI output, it can provide manual stepping and automatic waveform output functions.

The manual stepping output mode includes: 25% stepping and 100% stepping.

The output current is selectable from 0~20mA or 4~20mA.

Automatic wave output type includes: automatic step, sawtooth wave, triangle wave, and automatic waveform working parameters can be configured.

  • Internal 24V circuit power supply.
  • It has maintenance setup functions, including

Auto power-off, backlight, flashlight

  • Others
  • The segment code is displayed on an LCD with a white backlight.
  • It has a LED flashlight for lighting.
  • It is powered by 3 AA battery cells. The battery compartment door is convenient for battery replacement. Low-battery detection is available.
  • It is small, firm, reliable, suitable for field use, and cheap.
  • User-optional large-suction magnetic sling is provided.

II. Basic function and performance of the product (technical index)

Analog measurement function [Used within one year after calibration, 23 ℃± 5 ℃, 20-70% RH, accuracy=± (% set value+% reading)]

Output function Range Output range Resolution Accuracy Remarks

DC current

DCI

30mA 0.000mA~30.000mA 0.001mA 0.05%+4uA

At 20 mA, maximum load 1000Ω resistance

When simulating the transmitter, the external circuit power supply is 5~28V

Other characteristics:

  • Uncertainty includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
  • Maximum applied voltage at input end: about 30Vpk; Maximum applied current at input end: about 25mA
  • The temperature range of internal temperature compensated sensor RJC is -10 to 50°C. The temperature measurement accuracy at 18 to 28°C is ±0.5°C, and the temperature measurement accuracy at other temperature is ±1°C. Cold end compensation time is 10S/ times.
  • Temperature coefficient: 0.1 × basic accuracy/℃ (temperature range < 18℃ or > 28℃)

Input output function [Used within one year after calibration, 23℃±5℃, 20-70% RH, accuracy =+/-(% set point + reading %)]

Measurement function Range Measurement range Resolution Accuracy Remarks

DC voltage

DCV

35V -35.000V~35.000V 0.001V 0.02%+2mV Input resistance: approximately 1MΩ

DC current

DCI

30mA -35.000mA~35.000mA 0.001mA 0.02%+4uA

Shunt resistance: approximately 10Ω

Input resistance: approximately 20Ω

Loop power supply

LOOP

24 V 10%

Short circuit protection

Maximum current: 22 mA

Maximum input voltage: 60 V DC

Other characteristics:

  • Uncertainty includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
  • Display refresh rate: 2~3 times / second.
  • Maximum applied voltage at input end: 60 Vpk; Maximum applied current at input end: 50mA.

Current input protection: 100mA/250V Fast FUSE

  • Input common-mode rejection: 50Hz /60 Hz > 120 db; Input serial-mode rejection: 50Hz /60 Hz > 60 db
  • The temperature range of internal temperature compensated sensor RJC is -10 to 50°C. The temperature measurement accuracy at 18 to 28°C is ±0.5°C, and the temperature measurement accuracy at other temperature is ±1°C. Cold end compensation time is 10S/ times.
  • Temperature coefficient: 0.1 × basic accuracy / ℃ (temperature range <18℃ or >28℃)

III. General characteristics of the product

  • Operating temperature and humidity: 0 to 50ºC ≤80%RH without condensation; 40 to 50ºC ≤70%RH.
  • Storage temperature and humidity: -25 to 60ºC ≤90%RH without condensation.
  • Electrical safety: EN61010-1:2001

Withstand voltage: AC3540V(50/60Hz)/5 seconds between terminal and housing.

Insulation impedance: DC1000V/100MΩ or more between terminal and housing.

  • Electromagnetic compatibility (EMC): EN61326-1:2006

Performance criterion 2 is met, i.e. the function and performance are temporarily reduced or lost, but can be recovered by themselves.

  • Protection grade IP40.
  • Vibration and fall: IEC 60068-2-64:2008, IEC 60068-2-32:2008

Random, 2g, 5-500Hz; 1m drop test.

  • CE certification.
  • Quality standard: developed, designed and manufactured in accordance with TUV ISO 9001.
  • Calibration period and preheating time:

To ensure the accuracy of the Table, the calibration period is one year.

The startup preheating time is more than 30 minutes.

  • Instrument display and key

Segment code LCD display, white backlight

Rubber key is adopted

  • Instrument power supply

3 pcs of AA alkaline batteries for power supply

  • Dimension and weight

IV. Peripheral configuration of the product

  • Standard configuration

Industrial test conductor: 2 pairs

User’s Manual: 1 manual

AA alkaline battery: 3 pcs

Graphic carton: 1 item

Fuse: 2 pieces

High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibrator
High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibratorHigh Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibratorHigh Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibratorHigh Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibratorHigh Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibratorHigh Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibratorHigh Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibratorHigh Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibratorHigh Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibrator


Product Tags:

Current Loop Calibrator

      

Handheld auto signal generator

      

VICTOR 05+ Loop Calibrator

      
 High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibrator Manufactures

High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator current loop calibrator Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: XI'AN BEICHENG ELECTRONICS CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)